Making Diluted Solutions of MicroSpheres

From Advanced Projects Lab
Revision as of 15:46, 24 November 2014 by Wikiuser (talk | contribs)
Jump to: navigation, search

Procedure - From liquid with ~ 10% solids

  • Shake primary microsphere bottle to evenly disperse the particles.
  • Remove 100ul of cloudy white microsphere solution and dilute with 20ml of deionized water (200:1 dilution).

Anti-Stick Agents

  • Bovine Serum Albumin (BSA) at 20-25mg/ml in deionized water can be applied to the glass microscope slide (and coverslip) and allowed to evaporate off (to inhibit particle sticking to the glass surfaces).
  • For non-biological particles, 1% polyethylene glycol can be added to the microsphere solution as an anti-stick agent.
  • For biological particles the BSA application and Phosphate-Buffered Saline (PBS) (Sigma-Aldrich P5368-10PAK) can be used as anti-stick agents.

PBS Wikipedia

Students: If this recipe is inadequate (too many or too few particles) please revise.