Difference between revisions of "Making Diluted Solutions of MicroSpheres"
(Created page with "== Procedure - From Liquid with ~ 10% solids== * Shake microsphere bottle to evenly disperse the particles. * Remove 100ul of cloudy white microsphere solution and dilute wi...") |
|||
(7 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
− | == Procedure - From | + | === Procedure - From liquid with ~ 10% solids === |
− | * Shake microsphere bottle to evenly disperse the particles. | + | * Shake primary microsphere bottle to evenly disperse the particles. |
* Remove 100ul of cloudy white microsphere solution and dilute with 20ml of deionized water (200:1 dilution). | * Remove 100ul of cloudy white microsphere solution and dilute with 20ml of deionized water (200:1 dilution). | ||
− | ''Students: If this recipe is inadequate please revise '' | + | === Anti-Stick Agents === |
+ | |||
+ | * Bovine Serum Albumin (BSA) at 20-25mg/ml in deionized water can be applied to the glass microscope slide (and coverslip) and allowed to evaporate off (to inhibit particle sticking to the glass surfaces). | ||
+ | |||
+ | * For non-biological particles, 1% polyethylene glycol can be added to the microsphere solution as an anti-stick agent. | ||
+ | |||
+ | * For biological particles the BSA application and Phosphate-Buffered Saline (PBS) (Sigma-Aldrich P5368-10PAK) can be used as anti-stick agents. | ||
+ | |||
+ | * If particles begin to stick to the slide surfaces, a 3 minute sonication can increase the mobility of particles. | ||
+ | |||
+ | [http://en.wikipedia.org/wiki/Phosphate_buffered_saline PBS Wikipedia] | ||
+ | |||
+ | ''Students: If this recipe is inadequate (too many or too few particles) please revise. '' |
Latest revision as of 17:19, 4 September 2015
Procedure - From liquid with ~ 10% solids
- Shake primary microsphere bottle to evenly disperse the particles.
- Remove 100ul of cloudy white microsphere solution and dilute with 20ml of deionized water (200:1 dilution).
Anti-Stick Agents
- Bovine Serum Albumin (BSA) at 20-25mg/ml in deionized water can be applied to the glass microscope slide (and coverslip) and allowed to evaporate off (to inhibit particle sticking to the glass surfaces).
- For non-biological particles, 1% polyethylene glycol can be added to the microsphere solution as an anti-stick agent.
- For biological particles the BSA application and Phosphate-Buffered Saline (PBS) (Sigma-Aldrich P5368-10PAK) can be used as anti-stick agents.
- If particles begin to stick to the slide surfaces, a 3 minute sonication can increase the mobility of particles.
Students: If this recipe is inadequate (too many or too few particles) please revise.