<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://june.uoregon.edu/mediawiki/index.php?action=history&amp;feed=atom&amp;title=IR_laser</id>
	<title>IR laser - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://june.uoregon.edu/mediawiki/index.php?action=history&amp;feed=atom&amp;title=IR_laser"/>
	<link rel="alternate" type="text/html" href="https://june.uoregon.edu/mediawiki/index.php?title=IR_laser&amp;action=history"/>
	<updated>2026-04-06T00:39:06Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.31.0</generator>
	<entry>
		<id>https://june.uoregon.edu/mediawiki/index.php?title=IR_laser&amp;diff=787&amp;oldid=prev</id>
		<title>Wikiuser at 21:25, 21 August 2014</title>
		<link rel="alternate" type="text/html" href="https://june.uoregon.edu/mediawiki/index.php?title=IR_laser&amp;diff=787&amp;oldid=prev"/>
		<updated>2014-08-21T21:25:41Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class=&quot;diff diff-contentalign-left&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #222; text-align: center;&quot;&gt;Revision as of 21:25, 21 August 2014&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l2&quot; &gt;Line 2:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Installing IR laser to trap biological particles ==&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Installing IR laser to trap biological particles ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The optical tweezers setup was transitioned to an &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;infared &lt;/del&gt;laser to work with biological samples. This is necessary because biological systems will absorb the 637 nm wavelength light from the visible laser which in turn damages and kills the samples. Absorption of IR light does not occur, and therefore the same &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;systms &lt;/del&gt;will be unharmed by the IR laser.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The optical tweezers setup was transitioned to an &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;infrared &lt;/ins&gt;laser to work with biological samples. This is necessary because biological systems will absorb the 637 nm wavelength light from the visible laser which in turn damages and kills the samples. Absorption of IR light does not occur, and therefore the same &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;systems &lt;/ins&gt;will be unharmed by the IR laser&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;CAUTION: Always use the appropriate eye protection when operating this laser! It can cause permanent damage if proper safety precautions are not taken!&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;A 980 nm wavelength single mode fiber laser was used in a similar fashion as the 637 nm laser. To install, the fiber was connectorized to enable coupling into an infrared fiber collimator. Additionally Newport temperature controllers and laser diode drivers were installed to safely monitor the use of the IR laser. To operate, first stabilize the temperature controller at 20 degrees Celsius. Next, the current through the laser diode can be adjusted using the diode driver controller. It is recommended to use a power meter to determine a Power vs. Current relationship in order to establish a safe working range for the a laser. Finally replace the necessary optics in the system so that they are compatible with 980 nm wavelengths.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;Aligning this laser is more difficult because it is not visible to the naked eye. Getting the system well aligned with the 637 nm laser is beneficial, and then using an IR card and IR viewer are extremely helpful to seeing the beam. Again, be safe when initially working with the IR beam because it could be scattering off of various surfaces in your system&lt;/ins&gt;.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Wikiuser</name></author>
		
	</entry>
	<entry>
		<id>https://june.uoregon.edu/mediawiki/index.php?title=IR_laser&amp;diff=782&amp;oldid=prev</id>
		<title>Wikiuser: Created page with &quot; == Installing IR laser to trap biological particles ==  The optical tweezers setup was transitioned to an infared laser to work with biological samples. This is necessary bec...&quot;</title>
		<link rel="alternate" type="text/html" href="https://june.uoregon.edu/mediawiki/index.php?title=IR_laser&amp;diff=782&amp;oldid=prev"/>
		<updated>2014-08-21T21:04:52Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot; == Installing IR laser to trap biological particles ==  The optical tweezers setup was transitioned to an infared laser to work with biological samples. This is necessary bec...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&lt;br /&gt;
== Installing IR laser to trap biological particles ==&lt;br /&gt;
&lt;br /&gt;
The optical tweezers setup was transitioned to an infared laser to work with biological samples. This is necessary because biological systems will absorb the 637 nm wavelength light from the visible laser which in turn damages and kills the samples. Absorption of IR light does not occur, and therefore the same systms will be unharmed by the IR laser.&lt;/div&gt;</summary>
		<author><name>Wikiuser</name></author>
		
	</entry>
</feed>